Home

BACTEC full form

Description The BD BACTEC™ FX40 Automated Blood Culture System is an automated blood culture instrument used for the growth and detection of organisms present in blood samples. It uses BD's unique resin media, which neutralizes antimicrobials present in the blood allowing for faster recovery of organisms BD BACTEC ™ FX system. The BD BACTEC FX system features unique fluorescent sensor technology that allows for fully automated, walkaway testing. Hawkins R. Managing the pre- and post-analytical phases of the total testing process. Ann Lab Med. 2012;32:5-16

BACTEC MGIT 960 System This instrument is produced by Becton Dickinson (BD). It is specially designed to accommodate Mycobacteria Growth Indicator Tube (MGIT) and incubate them at 37°C. The instrument scans the MGIT every 60 minutes for increased fluorescence Blood Culture Media: Draw 20 mL of blood and aseptically inoculate 10 mL into each of the 2 bottles: BACTEC PLUS (blue label) and BACTEC LYTIC (purple label). Use an alcohol prep to clean the top of each bottle before and after inoculation The patient's full name, date of birth or health card number, the source of the fluid and date and time of collection should be specified on the requisition and specimen container. Fluids for culture should be submitted as described below. Provide any relevant clinical information on the requisition The high efficiency of the BACTEC TB System is due to the use of liquid medium. Moreover, a growth enhancing substance is added to the medium to further reduce the detection time.11 Since the introduction of the BACTEC 460 TB System, it has been established that liquid medium is far superior to solid media for recovery, time-to-detectio

Type. Lytic / 10 Anaerobic / F Culture. UNSPSC Code. 41104110. Features. The BD BACTEC vials are ready for use as received and require no reconstitution or dilution. Store at 2 - 25 ° C in a dry location, out of direct light. For Use With (Equipment) : Bactec 9240, 9120 and 9050 System. Principal use is with the BACTEC fluorescent series. Blood Culture Media BD Bactec™ Lytic / 10 Anaerobic / F Culture Liquid. The BD BACTEC vials are ready for use as received and require no recon Store at 2 - 25 ° C in a dry location, out of direct light For Use With (Equipment) : Bactec 9240, 9120 and 9050 Syste BD BACTEC FX40 system service training. 1. BACTEC FX40 System Service Training Manual System Operation Module A BD Diagnostic Systems Systems Support Engineering & Technology Transfer 7 Loveton Circle Sparks, MD 21152 E-mail: product_support@bd.com Confidential and proprietary. For BD Worldwide Support use only For the diagnosis of prosthetic joint infection (PJI) automated BACTEC™ blood culture bottle methods have comparable sensitivity, specificity and a shorter time to positivity than traditional cooked meat enrichment broth methods. We evaluate the culture incubation period required to maximise sensitivity and specificity of microbiological diagnosis, and the ability of BACTEC™ to detect slow.

Objectives: Rapid detection of Mycobacterium tuberculosis (MTB), especially multidrug-resistant strains, is of importance for prompt clinical management and initiation of public health control measures. Culture remains the gold standard in the confirmatory laboratory diagnosis of mycobacterial infections. The reliability of the automated radiometric BACTEC 460 TB (BACTEC) system for the. We conclude that the BacT/Alert and BACTEC 660/730 nonradiometric systems are comparable for recovering clinically significant microorganisms form adult patients with bacteremia or fungemia, but that the BacT/Alert system detects microbial growth earlier than the BACTEC system does, with significantly fewer false-positive results Description. Creates an environment suitable for rapid mycobacterial growth. Recommended for testing sputum, stool specimens, body fluids and tissue. The tube uses fluorometric technology to aid in the reading of results. Under UV light, a positive test emits a vivid orange fluorescent glow at the tube base and at the meniscus; a negative test.

BACTEC MGIT 960 TM system was 82.8%, while that of Lowenstein-Jensen medium was 75.9%. The mean time for detection of Mycobacteria was 17.8 ± 0.9 days and 46.5 ± 0.4 days for BACTEC MGIT 960 TM system and Lowenstein-Jensen medium, respectively while the contamination rate with BACTEC AFB-Isolation by Rapid Culture by Bactec MGIT BAL & other Respiratory Sample BACTEC(aerobic)=BACTECPlusAerobic/F;BACTEC(anaerobic)=BACTECPlusAnaerobic/F The BACTEC MGIT 960 culture tube contains 7 ml Middle brook 7H10 broth base, in which an enrichment supplement containing oleic acid, albumin, dextrose, and catalase is added

BD™ BACTEC™ FX40 Automated Blood Culture - Fisher Sc

FAN vs. BACTEC Plus. Ziegler R, Johnscher I, Martus P, Lenhardt D, Just HM. Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media in automated blood culture systems to detect bloodstream infections. J Clin Microbiol. 1998; 36(3):657-661. Pohlman JK, Kirkley BA, Easley KA, Basille BA, Washington JA Centurion Service Group. 708-761-6655. Visit website. See all auctions. Favorite. Get alerts for new items like this. Description. BECTON DICKINSON BACTEC 9240 AUTOMATED BLOOD CULTURE SYSTEM, UPPER UNIT W/PC, SOFTWARE V.4.91A (2010) AND BECTON DICKINSON BACTEC 9240 AUTOMATED BLOOD CULTURE SYSTEM, LOWER UNIT, STACKED ON METAL FRAME Inject 10 mL into a BacTec Plus + aerobic bottle and 10 mL into a BacTec Lytic/10 anaerobic bottle. Preferably in one-half hour, collect an additional 20 mL of blood to be inoculated as above. Note: If a Catheter Related Sepsis (Quantitative), fungal, or mycobacterial blood culture is ordered, draw a 10mL Isolator tube for each of these. BACTEC-positive samples were screened for purity by sub-culturing on blood agar plates. Two hundred and fifty three (253) samples with Acid fast bacilli (AFB, 174 BACTEC MGIT 960 and 79 BACTEC 9120 blood cultures) were analyzed for presence of MTC using Capilia TB and in-house PCR assays Comparison of BACTEC Plus Aerobic/F, Anaerobic/F, Peds Plus/F, and Lytic/F Media with and without Fastidious Organism Supplement to Conventional Methods for Culture of Sterile Body Fluids DeAnna D. Fuller and Thomas E. Davis We compared the BACTEC 9240 continuous-read instrument using Peds Plus/F, Lytic/F, Aerobic/F, and Anaerobic/F tnedia (Becton Dickinson Diagnostic Instrument Systems.

BD BACTEC™ Blood Culture Media - B

Full-Time Job Description SummaryBe part of something bigger! Production Operator will operates all the filling and labeling machines as well as auxiliary equipment to produce Bactec products. Performs set-up and cleaning of equipment. Notifies immediately the Manufacturing Facilitator or designee of any deviation form normal operation. To compare the yield of two aerobic and an anaerobic BACTEC blood culture media in detecting bacteremia in ambulatory and hospitalized care settings at a children's hospital, a prospective cohort study was completed. Over an 18-month period, equal blood volumes (minimum of 1 mL/bottle) were inoculated into a three-bottle culture set including. Each medium was inoculated in a pair of Bactec Plus Aerobic/F and Bactec Lytic/10 Anaerobic/F blood bottles and placed in a Bactec 9240 incubator for 14 days at 37°C and in a Sabouraud broth at 20°C. Changes in colour or turbidity of storage media were evaluated daily at the corneal bank. Recipients were screened post-graft for infectious signs

Mycobacteria growth indicator tube - Wikipedi

  1. Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria N. Williams-Bouyer, R. Yorke , H. I. Lee, G. L. Woods Academic Institut
  2. In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic.
  3. ants. In Australia, New Zealand, the United States, and some other countries, the Bactec 460 system with modified Bactec 12B medium (Becton, Dickinson) has been the most commonly used liquid culture system, but it.
  4. The BD BACTEC™ FX40 Automated Blood Culture System is an automated blood culture instrument used for the growth and detection of organisms present in blood samples. It uses BD's unique resin media, which neutralizes antimicrobials present in the blood allowing for faster recovery of organisms
  5. Bactec Peds Plus / F Medium by BD. Manufacturer: BD. Aerobic medium for blood cultures in children. Specialized media that accommodate small-volume samples to help optimally detect common pediatric and nonpediatric organisms. Made of enriched soybean-casein digest broth. Medium contains resins for antibiotic neutralization
  6. BD FOS™ is provided in a lyophilised form along with a special BD BACTEC™ FOS™ Reconstituting Fluid (BD FOS™ RF) for use with BD BACTEC™ media to enhance the growth of fastidious organisms, such as Haemophilus spp. and Neisseria spp. 1 set is sufficient to inoculate 20 - 24 blood culture vials
  7. INSTRUMENT 1. BACTEC™ 9240/9120/9050 (BACTEC Fluorescent Series) Microorganisms, if present in the blood samples, metabolize nutrients in the BACTEC culture vial and release CO2 into the medium or utilize the oxygen in the medium. The instrument monitors the fluorescence of the vial sensor which increases as CO2 is produced or oxygen is utilized

The BACTEC FX System has a compact and versatile system design, It offers a 200-vial benchtop unit or a full 400-vial stack that includes an embedded, centralized computer - all in a highly. BD is a global medical technology company that is advancing the world of health by improving medical discovery, diagnostics and the delivery of care. BD leads in patient and healthcare worker safety and the technologies that enable medical research and clinical laboratories. The company provides innovative solutions that help advance medical. The mean times to detection of all mycobacteria with BACTEC 9000 MB and BACTEC 460 TB were similar (10.3 and 10.0 days, respectively). The results obtained indicate that the nonradiometric BACTEC (BACTEC 9000 MB) system is as efficient as Bactec 460 TB and significantly more efficient than LJ for the rapid recovery of mycobacteria from both. • Blood culture: Bactec pedi bottle (no minimum amount needed) • Hold extra red top tube for future studies, if able **all tubes being sent need to be full if you wish the lab to run multiple tests off of the same tube - minimum volumes added together will not suffice** • Lavender top EDTA tube (not the bullet): o Amount of blood: needs.

Isolation ofMycoplasmahominis usingtheBACTEC9000series bloodculturesystem Table 1 Isolation ofMhominisfromBACTECPlus/F media Daysto isolation Inoculum BACTEC BACTEC Isolate (cfu/1O ml) BHIbroth (aerobic) (anaerobic) A 70 1 Nogrowth 7 B 260 1 Nogrowth 7 C 150 1 Nogrowth 6 D 30 1 Nogrowth Nogrowth E 40 1 Nogrowth Nogrowth BACTEC(aerobic) =BACTECPlusAerobic/F; BACTEC (anaerobic. E-mail: luqmansatti@hotmail.com Received 4 December 2009; received in revised form 26 February 2010; accepted 4 March 2010 _____ ABSTRACT We evaluated the performance of MGIT 960 system in terms of recover rate, detection time of mycobacteria and contamination rate from various human clinical specimens and compared it with already in use BACTEC. The blood volume cultured in the detection of bacteraemia is a major variable in treating patients with systemic inflammatory response syndrome. The fact that drawing optimal volumes (8-10 mL) of blood for culture increases the sensitivity of the method is well established. This study aimed to optimise the mean blood volumes (mBVs) to that recommended level in a small rural hospital by.

Specimen Requirements/Containers Department of Pathology

An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens By Bactec MGIT 960, positive signals were detected in 57 of the 164 samples. Out of these, 43 were identified as M. tuberculosis by PNB test and 5 as NTM. The remaining nine, Bactec MGIT 960 positive samples, were found to have Cryptococcus in six and other contaminants in three samples when examined microscopically (false positives). Bactec.

BD 442021 - McKesson Medical-Surgica

The aim of this study was to evaluate the ability of the commercial COBAS AMPLICOR MTB amplification system to identify Mycobacterium tuberculosis (M. tuberculosis) in positive BACTEC MGIT 960 cultures in routine clinical practice.Methods: We tested 270 positive BACTEC MGIT 960 cultures with the COBAS AMPLICOR MTB at Taipei Medical University. BACTEC 12B vials, 5 ml of unprocessed blood for BACTEC 13A vials, and 4 drops (approximately 0.1 ml) for each of two L-J slants. ESP bottles were incubated at 35°C in the instrument for 42 days or until a positive signal was obtained. BACTEC vials were incubated at 36°C and read with the BACTEC 460T

BD 442265 - McKesson Medical-Surgica

  1. ation. Three groups of febrile pediatric patients with blood cultures growing CoNS were identified: Group 1, children with vascular catheter-associated bloodstream infection; Group 2, previously healthy children with.
  2. The results of BACTEC blood culture showed positive BACTEC blood culture in 3 (10%) and 0 (0%) patients in the control and case groups, respectively. Moreover, no significant difference was noticed between the two groups in terms of BACTEC blood culture (P = 0.076). Table 2 shows the frequency of patients in terms of procalcitonin level. Table 2
  3. Mycobacterium tuberculosis converts pyrazinamide to its active form by using the enzyme pyrazinamidase. This enzyme is coded for on the pncA gene, and mutations in the pncA gene result in absence of active enzyme, conferring resistance to the drug pyrazinamide. We investigated 27 strains of Mycobacterium tuberculosis suspected of being multidrug resistant
  4. ated BACTEC 12B broth cultures by testing with amplified mycobacterium tuberculosis direct test'. Together they form a unique fingerprint. Mycobacterium tuberculosis Medicine & Life Science

BD BACTEC FX40 system service trainin

A 1-day delay in calculating the BACTEC data after the control vial reading was equal to or greater than 30 resulted in a 25% reduction in the calculated level of resistance (0.7 to 0.53). By adhering exactly to the recommended procedures for the BACTEC test method and by using log-phase inocula, this method shows better precision and accuracy. For the BACTEC system, remaining levels were 0 to 30% of vancomycin and 0% of cefoxitin. Under these simulated conditions, the BACTEC PLUS system was superior to the BacT/Alert FA system in recovering gram-positive and gram-negative bacterial pathogens in the presence of β-lactam antibiotics, gentamicin/penicillin, and vancomycin Aims —To compare the recovery of mycobacteria from clinical samples using the MB/BacT rapid culture system with that obtained using egg medium or the Bactec radiometric method. Methods —The three methods were compared using 681 clinical samples (462 respiratory and 219 non-respiratory samples) and eight external quality control strains. Culture media were incubated at 35-37°C for six. Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients

Fingerprint Dive into the research topics of 'Comparison of BD Bactec Plus Aerobic/F medium to VersaTREK redox 1 blood culture medium for detection of Candida spp. in seeded blood culture specimens containing therapeutic levels of antifungal agents'. Together they form a unique fingerprint. Antifungal Agents Medicine & Life Science The sensitivity was superior to standard BACTEC blood culture (86.3% vs 72.8%), and higher than our previous estimate (75.0% in 20 cases), likely reflecting a more precise measure due to the increased sample size . We also found the Mp1p EIA to be sensitive when testing urine, comparing favorably with plasma and offering significantly increased.

Use of an automated blood culture system (BD BACTEC™) for

For a full list of topics: A-Z Index. Search Dropdown. Submit. For a full by the 2009 implementation of the new culture system MGIT 960 because its sensitivity is equivalent to that of the BACTEC TB 460 system used previously in combination with Please use the form below to submit correspondence to the authors or contact them at the. For BACTEC MGIT 960, these times (mean of 13.1 days for all mycobacteria and 12.8 days for MTBC) are comparable to the mean times to detection reported by other investigators (11.8 to 13.3 days for all mycobacteria and 12.6 to 14.4 days for MTBC) (2, 4, 10) All the positive BACTEC blood culture samples from January 2012 to December 2016, of patients above 18 years of age, were included in the study. RESULTS: During the study period of 5 years, out of 11,966 BACTEC samples, 932 ( 7.78%) were positive Brucella spp. are Gram-positive, rod-shaped, and spore-forming bacilli. Brucella abortus and B. melitensis are the main causes of brucellosis.The aim of the study was to establish a rapid and simple molecular method for the detection of this disease.Forty-five Brucella spp. were isolated from blood samples using the BACTEC Fluorescent 9050 system and were detected by anti-IgM or IgG Brucella. The global expansion and local spread of tuberculosis (TB) have been shaped by patterns of human migration (1-4).The 258 million international migrants who live outside their country of birth are frequently put at high risk for TB disease and death because of the many health risks associated with migration including limited access to healthcare (5,6)

on case report form (CRF). Biological specimens were collected from those partic-ipants suspected to have HAI. The specimens were in-vestigated by microbiological methods following WHO manual to isolate the culprit bacteria [31]. Furthermore, blood culture was done by using BD BACTEC™ FX40 blood culture system as per manufacturers' instruction Background . The viable mycobacterial bacilli can sometimes form granules in the Mycobacterium Growth Indicator Tube (MGIT) to produce instrument-negative outcomes when BACTEC MGIT 960 culture is performed. The cause of this phenomenon has never been analyzed. Methods . Thirty-one instrument-negative, granule presenting MGIT vials were collected for conducting acid-fast staining and also.

Efficacy of BACTEC TB in the rapid confirmatory diagnosis

  1. Capilia TB is a simple immunochromatographic assay based on the detection of MPB64 antigen specifically secreted by the Mycobacterium tuberculosis complex (MTC). Capilia TB was evaluated for rapid identification of MTC from BACTEC MGIT 960 and BACTEC 9120 systems in Kampala, Uganda. Since most studies have mainly dealt with respiratory samples, the performance of Capilia TB on blood culture.
  2. Pyrazinamide (PZA) is an important component of first-line drugs because of its distinctive capability to kill subpopulations of persistent Mycobacterium tuberculosis (MTB). The prodrug (PZA) is converted to its active form, pyrazinoic acid (POA) by MTB pncA-encoded pyrazinamidase (PZase). Mutation in pncA is the most common and primary cause of PZA resistance
  3. Many laboratories validate DST of the second-line drugs by BACTEC MGIT 960 system. The objective of this study is to evaluate the critical concentration and perform DST for the 2nd line drugs. We evaluated 193 clinical strains of M. tuberculosis isolated from patients in South Korea. Testing the critical concentration of six second-line drugs was performed by MGIT 960 and compared with L-J.
  4. Conclusions. BACTEC media has faster time to detection and increased bacterial recovery over the BacT/Alert media in the following categories: overall growth, pathogens, septic events, gram-positive cocci, gram-negative rods, Staphylococcus aureus, and cultures where antimicrobials were dosed up to 48 hours before culture collection

Controlled comparison of the BacT/Alert and BACTEC 660/730

The BACTEC 9240 (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is a new continuous-monitoring blood culture system that uses internal, fluorescent-CO2 sensors. In a multicenter clinical trial, organism yield and times to detection with the prototype BACTEC 9240 system were compared with those of the BACTEC NR 660 system. Equal volumes of blood were inoculated into the bottles.

BDBBL MGIT Mycobacteria Growth Indicator Tube: Reagents

  1. BACTEC MGIT 960 TM system for screening of Mycobacterium
  2. AFB-Isolation by Rapid Culture by Bactec MGIT BAL & other
  3. Performance of Mycobacterium Growth Indicator Tube BACTEC
  4. BacT/ALERT 3D Microbial Identification System bioMérieu
  5. Becton Dickinson Bactec 9240 Automated Blood Culture
  6. Blood Culture Collectio
  7. Evaluation of Capilia TB assay for rapid identification of

Comparison of BACTEC plus Aerobic/F, Anaerobic/F, Peds

Development and Validation of a Liquid Medium (M7H9C) for

Evaluation of a nonradiometric system (BACTEC 9000 MB) for

  1. (PDF) Evaluation of the BACTEC™ MGIT™ 960 system for the
  2. Education and coaching to optimise blood culture volumes
  3. Culture with BACTEC Peds Plus/F bottle compared with
  4. Laboratory Diagnosis of Tuberculous Meningitis - Is There
  5. Blood culture - Microbiolog
  6. Delamanid susceptibility testing of Mycobacterium
  7. Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems

Comparison of two pretreatment methods for the detection